http://www.linkfixerplus.com ==== Sponsor: Argent Software ==== NETWORK TESTING LABS COMPARES ARGENT TO MOM 2005 Network Testing Labs, one of the world's leading independent research companies, concluded that "Argent's suite had a smaller footprint, was more scalable, supported more platforms, had a more responsive and intuitive user interface and gave us more useful reports," the report says. "Argent's suite of monitoring products emerged from our testing with flying colors." Download this FREE Comparison Paper now: http://www.argent.com/w/whitepapers_mom.html?Source=WNT

==========

FAQs
Q. How can I modify the Microsoft Exchange Server 2003 Outlook Web Access (OWA) timeout that's applied when OWA has forms-based authentication enabled?
Q. Where can I find details about the new ADMX format that Windows Vista and Longhorn Server use? Q. Where are custom .adm files stored in Group Policy Objects (GPOs)?
Q. How can I control which .adm files are used when editing a Group Policy Object (GPO)? Q. How do I enable logging for Automated Deployment Services (ADS) deployments? ==== Sponsor: TNT Software ==== Download a Tool that will Benefit any Sys Admin Are you searching for an affordable real-time monitoring toolset that will support your proactive system management objectives? Start NOW and download ELM Enterprise Manager from TNT Software. Within an hour, you will experience for yourself why ELM is recognized as the tool that will benefit any System Administrator. Before the 30 Day full feature trial is completed, the Monitoring, Alerting and Reporting will have saved you time and provided you the data for prompt corrective action. Be Proactive; and download ELM Enterprise Manager from the link below: http://www.tntsoftware.com/wintips091806

==========

==== FAQs ====
by John Savill, FAQ Editor, [email protected] Q. How can I modify the Microsoft Exchange Server 2003 Outlook Web Access (OWA) timeout that's applied when OWA has forms-based authentication enabled? A. By default, when OWA has forms-based authentication enabled, sessions have a 15-minute inactivity timeout for public or shared computers and 24 hours for a private computer. If you're using a public computer to compose a long email message that takes more than 15 minutes to write, the session will time out and you won't be able to send the message. You can change this timeout value (which is the cookie lifetime) by using this procedure:
1. Log on to the Exchange server as an Administrator.
2. Start the registry editor (regedit.exe).
3. Navigate to the HKEY_LOCAL_MACHINESYSTEMCurrentControlSetServicesMSExchangeWEBOWA subkey.
4. From the Edit menu, select New - DWORD value.
5. Enter a name of PublicClientTimeout and press Enter.
6. Double-click the new value and set it to the desired number of minutes before a timeout (1 to 4320), set the type to decimal, and click OK.
7. To set the timeout period for a private client, repeat the process of creating a DWORD value, but this time enter a name of TrustedClientTimeout and again set the value to the number of minutes before a timeout (The value for private computers should be significantly higher than for public computers.)
8. Stop and restart the World Wide Web (WWW) Publishing service by using these commands at the command line. net stop w3svc net start w3svc -------------------- Q. Where can I find details about the new ADMX format that Windows Vista and Longhorn Server use? A. New XML-based ADMX files, which replace the .adm files that earlier Windows versions use, let you control policy settings in Vista and Longhorn Server. An ADMX file is defined as a set of one language neutral file (.admx) and associated ADMX language resource files (.adml). This language independence helps policies display correctly in local administrator environments and tools. Microsoft has released the schema for the new ADMX format, and you can download it at http://go.microsoft.com/fwlink/?LinkID=71180 . ADMX files will reside in the Central Store, which is replicated as part of the SYSVOL structure. This approach avoids current problems that occur when using .adm files, which are stored as part of the Group Policy Object (GPO) in the adm subfolder of the GPO and thus cause replication effort between domain controllers (DCs). With Vista and Longhorn Server, when you edit a GPO, the associated ADMX files are read from the Central Store instead of being stored with each GPO that uses them, cutting down on replication. The Central Store is optional and isn't created by default; you must manually configure it. -------------------- Q. Where are custom .adm files stored in Group Policy Objects (GPOs)? A. When you create a new GPO, a folder is created under the Domain Controller's (DC's) Sysvol folder (Policies\{} ). Under that structure, a subfolder is created named Adm that has a copy of all the .adm files that are used as Administrative templates, which by default include conf.adm, inetres.adm, system.adm, wmplayer.adm, and wuau.adm. The files total nearly 3.5M, which is a common issue with GPO replication today; these .adm files are replicated between DCs and replicated for every GPO, which can cause a significant amount of traffic if an ADM file is updated). When you import a new .adm file into the Administrative templates section of a GPO, the .adm file is copied into the GPO's Adm subfolder, which is then replicated via the File Replication Service (FRS) to all other DCs. -------------------- Q. How can I control which .adm files are used when editing a Group Policy Object (GPO)? A. By default, when you edit a GPO, two things happen: The GPO is read from the domain controller (DC) that hosts the PDC Flexible Single-Master Operation (FSMO) role, and the .adm files that are used are read from the Group Policy Template, which is the file-based portion of the GPO that's stored in the DC's Sysvol folder. It's possible to configure .adm files to instead be loaded from the %windir%inf folder of the machine editing the GPO. This approach could be useful in situations in which, for example, different language versions of the .adm files exist that will let you perform localized editing to show the localized explanation text instead of the language that created the GPO. To enable this via Group Policy, open a GPO that applies to computers that want to use local .adm files and perform the following steps:
1. Navigate to Computer Configuration, Administrative Templates, System, Group Policy. 2. Double-click "Always use local ADM files for Group Policy Object Editor."
3. Set to "Enabled" and click OK, as the figure at http://www.windowsitpro.com/articles/images/gpuselocaladm.gif shows.
4. Close the Group Policy Object Editor. You can also configure this by editing the registry and setting the value of the HKEY_LOCAL_MACHINESoftwarePoliciesMicrosoftWindowsGroup PolicyOnlyUseLocalAdminFiles to 1. Be aware that setting this value means if custom .adm files were used that don't exist on the machine editing the GPO, then some settings might not be displayed (but since settings are actually stored in the Registry.pol file, it doesn't mean they will no longer be applied to Group Policy-targeted machines). -------------------- Q. How do I enable logging for Automated Deployment Services (ADS) deployments? A. To enable detailed logging for the ADS process to the %windir%TracingAdsbuildsvc.log file perform the following steps:
1. Start the registry editor (regedit.exe).
2. Navigate to HKEY_LOCAL_MACHINESOFTWAREMicrosoftTracingAdsBuilderSvc.
3. From the Edit menu, select New - DWORD value.
4. Enter a value name of EnableFileTracing and press Enter.
5. Double-click the new value and set it to 1. Click OK. -------------------- ==== Hot Release ==== Broken links during data migrations? Patented LinkFixerPlus is the first application that automatically fixes broken links in Excel, Word, Access, AutoCAD, InDesign, PDF and other files when performing data migrations due to: server consolidations, server name changes, path name changes or folder reorganizations. Detailed broken link reporting too! Download your trial version now! http://www.linkfixerplus.com

==============================

Events and Resources: http://www.windowsitpro.com/events Windows Connections Conference Now in its seventh year, Windows Connections returns November 6-9, to Mandalay Bay in Las Vegas. Don't miss your chance to interact with industry experts and hear the latest information on Windows Server 2003, Windows 2000 Server, and Windows XP Professional! Register and attend sessions at Microsoft Exchange Connections FREE!
http://www.winconnections.com ORACLE AND SQL... BETTER TOGETHER? Learn about optimizing 64-bit database computing, business intelligence for SQL Server and Oracle, high-availability proof points for database computing, and the implications of architectural differences between Oracle and SQL. Coming to 12 US cities in September and October. Special price--sign up now for just $49!
http://www.windowsitpro.com/roadshows/sqloracle/?code=enews0906 How will compliance regulations affect your IT infrastructure? Help design your retention and retrieval, privacy, and security policies to make sure that your organization is compliant. Download the free eBook today!
http://www.windowsitpro.com/go/ebooks/sherpa/compliance/?code=0920emailannc Total Cost of Ownership--TCO. It's every executive's favorite buzzword, but what does it really mean and how does it affect you? In this podcast, Ben Smith explains how your organization can use virtualization technology to measurably improve the TCO for servers and clients.
http://www.windowsitpro.com/go/podcast/hp/virtualization/?code=0920emailannc When your systems go down, your users' productivity grinds to a halt. User downtime is one of the fastest growing concerns among businesses. This free Web seminar teaches you how to keep your users continuously connected and your business up and running. View the on-demand Web seminar now!
http://www.windowsitpro.com/go/seminars/neverfail/usercontinuity/?code=0920emailannc

==============================

==============================

==========

==== Contact Us ==== About the newsletter -- [email protected] About technical questions -- http://www.windowsitpro.com/forums About product news -- [email protected] About your subscription -- [email protected] About sponsoring UPDATE-- [email protected]

===============

This email newsletter is brought to you by Windows IT Pro, the leading publication for IT professionals deploying Windows and related technologies. Subscribe today.
https://store.pentontech.com/index.cfm?s=1&promocode=eu205xxb

Make sure your copy of Windows Tips & Tricks UPDATE isn't mistakenly blocked by antispam software! Be sure to add [email protected] to your list of allowed senders and contacts.

Manage Your Account You are subscribed as %%$email%%

You are receiving this email message because you subscribed to this newsletter on our Web site. To unsubscribe, click the unsubscribe link:

http://list.windowsitpro.com/u?id=%%SUBSCRIBER_ID_TAG%%

View the Windows IT Pro Privacy policy at http://www.windowsitpro.com/AboutUs/Index.cfm?action=privacy

Windows IT Pro, a division of Penton Media, Inc. 221 East 29th Street, Loveland, CO 80538, Attention: Customer Service Department

Copyright 2006, Penton Media, Inc. All Rights Reserved.

About the Author

Sign up for the ITPro Today newsletter
Stay on top of the IT universe with commentary, news analysis, how-to's, and tips delivered to your inbox daily.

You May Also Like